Description:

The synchronous counter in this package can be preset and also has an internal carry look-ahead for fast counting schemes and for cascading Without the need of additional logic.

 

Functional Diagram and/or Package:


 

 

 

Pin Names:

Vdd - Positive Supply Voltage (3V to 15V)

Vss - Ground

CLK - Clock

CL - Clear

P EN, T EN - Enable Inputs

RC - Ripple Carry

LD - Load

QA, QB, QC, QD - Outputs

INA, INB, INC, IND – Inputs

 

Logic Waveforms:

 


 

 

 

Operation Mode:

The Clear (CL) function is asynchronous. CL=1 sets the outputs to “0”.

When Load (LD) is “0”, the counter is disabled and causes the output to agree with the setup data after the next clock pulse, regardless of the levels in ENs inputs (P EN and T EN).

Counting is enabled when P EN and T EN are “1”.

 

Electrical Characteristics:

 


 

 

 

Other Devices:

The 40160, 40162, and 40168 are devices of the same group with small differences in the operational mode.

 

Applications:

Programmable Counters

Frequency Dividers

Timers

 

Observations:

This device is compatible with the TTL 74161.

 

 

 