Figure bellow shows the basic configuration for a conventional Voltage Doubler.

 

The working voltage of the capacitor (minimum WVDC) is calculated by the next formula:

 

 


 

 

 

Formula 2

Voltage doubler:

Vc1 = Vc2 = Vmax

 

Where:

Vc1 and Vc2 are the capacitors working voltage in volts (V)

Vmax is the peak value of the input AC voltage in volts (V)

 

Note: Minimum PIV of the diodes is 2 x Vmax

 

 