2024_09_boom

In the non inverting configuration the phase of the input signal is the same of the output signal. The gain is determined by the feedback resistance. The basic circuit of a non-inverting operational amplifier application is shown in figure bellow. The following formula is used to determine the gain.

 


 

 

 

Formula:

Gain:

G = 1 + (R2 / R1)

 

Where:

G is the gain

R1 and R2 are the resistances in ohm (Ω)

 

 

Formula:

Voltage gain:

Vout = Vin x [ 1+ (R2 / R1) ]

 

Where:

Vout is the output voltage in volts (V)

Vin is the input voltage in volts (V)

R1 and R2 are the resistances in ohm (Ω)

 

Note: the output voltage cannot exceed the power supply voltage.

 

Application example:

In the circuit shown in figure above, R2 is a 100 kΩ resistor and R1 is a 10 kΩ resistor. Determine the gain.

 

Data:

R1 = 10 kΩ

R2 = 100 kΩ

G = ?

 

Applying formula:

G = 1 + [ (100 x 103) / (10 x 103) ]

G = 1 + 10

G = 11

 

 

Datasheets


N° of component